不二工機製品案内
41/112

HHSSHLLLLLHHHSSSL膨張弁容量変化表(kW)形 式使用冷媒M2-524 / 534M2-824 / 834M2-1224 / 1234M2-1924 / 1934M2-2534M2-3034M2-2734M2-3734R134aM2-524 / 534M2-824 / 834M2-1224 / 1234M2-1924 / 1934M2-2534M2-3034M2-2734M2-3734R407CM2-524 / 534M2-824 / 834M2-1224 / 1234M2-1924 / 1934M2-2534M2-3034M2-2734M2-3734R404A●凝縮温度:38℃、過冷却度:0℃、過熱度変化:4℃(R134a)、3.5℃(R407C・R404A)の各相当圧力時の容量。●配管やエバポレータなどの圧力損失が0とした時のものです。容量変化表(kW)形 式使用冷媒M2-524T / 534TM2-824T / 834TM2-1224T / 1234TM2-1924T / 1934TR448AM2-2534TM2-3034TM2-2734TM2-3734TM2-524T / 534TM2-824T / 834TM2-1224T / 1234TM2-1924T / 1934TR449AM2-2534TM2-3034TM2-2734TM2-3734TM2-524T / 534TM2-824T / 834TM2-1224T / 1234TM2-1924T / 1934TM2-2534TM2-3034TM2-2734TM2-3734TR407HR134a、R407C、R404A−35℃−−−−−−−−0.671.21.93.04.04.87.510.40.480.851.32.22.93.53.57.7−40℃−−−−−−−−0.551.01.52.43.23.96.08.30.400.711.11.82.42.94.66.3−45℃−−−−−−−−−−−−−−−−0.330.580.811.41.92.33.64.9R448A、R449A、R407H−30℃−35℃0.631.11.82.83.84.57.19.80.611.11.82.83.74.46.99.50.751.32.23.44.55.58.511.7−40℃0.510.91.42.33.03.75.77.90.500.881.42.23.03.65.67.70.621.11.72.73.74.46.99.50.71.32.03.24.35.28.111.20.691.21.93.24.25.17.911.00.841.52.43.95.26.39.713.4公称容量kW1.11.82.85.68.411.316.922.51.11.82.85.68.411.316.922.50.71.11.83.55.37.010.614.110℃0.801.52.74.76.57.912.218.51.42.64.78.311.313.921.430.40.981.93.46.28.310.215.622.35℃0.771.42.54.35.97.211.115.61.42.54.47.810.713.120.128.50.971.83.25.87.89.614.720.9公称容量10℃1.32.54.47.810.713.220.328.81.32.44.37.610.512.919.828.21.62.95.29.112.615.423.733.715℃1.32.64.68.311.414.021.530.71.32.54.58.111.113.621.030.01.63.05.49.713.316.325.135.8kW1.11.83.55.37.010.614.117.61.11.83.55.37.010.614.117.61.11.83.55.37.010.614.117.6蒸  発  温  度−10℃0.591.11.83.04.04.97.610.71.22.13.66.18.210.015.521.70.841.52.64.46.07.311.315.9−5℃0.671.22.03.54.75.78.812.41.32.33.96.79.111.117.224.20.911.72.85.16.88.312.818.00℃0.731.32.34.05.46.610.214.31.32.44.27.410.012.319.026.70.941.83.15.57.39.013.819.5−15℃0.550.991.62.73.64.46.99.61.11.93.25.47.28.813.619.00.771.42.34.05.36.510.114.1蒸  発  温  度0℃1.32.34.07.09.511.617.925.31.22.23.96.89.311.417.624.71.52.74.78.211.213.721.129.7●凝縮温度: 38℃、過冷却度: 0℃、過熱度変化: 3.5℃の各相当圧力時の容量。●配管やエバポレータなどの圧力損失が0とした時のものです。5℃1.32.44.27.410.112.419.127.01.32.34.17.29.912.118.726.41.52.84.98.711.814.522.331.6−5℃1.22.23.76.48.610.516.322.91.22.13.66.28.510.315.922.41.42.64.37.510.212.419.226.9−10℃−20℃0.490.871.42.33.13.85.98.21.11.72.84.76.47.711.916.60.701.32.13.54.75.78.812.3−25℃0.430.781.22.02.73.35.17.10.861.52.44.15.46.610.214.20.621.11.83.04.04.87.510.4−30℃0.410.721.11.82.43.04.66.40.741.32.13.44.65.58.611.90.560.991.62.63.54.26.59.0−15℃−20℃0.931.7 2.7 4.5 6.0 7.3 11.3 15.7 0.91 1.62.64.4 5.9 7.1 11.0 15.4 1.1 2.0 3.25.3 7.1 8.7 13.4 18.7 −25℃0.811.42.33.85.16.29.613.40.791.42.33.75.06.19.413.10.961.72.84.66.17.411.515.91.12.03.45.77.89.514.620.51.123.35.67.69.314.320.01.32.44.06.89.211.217.324.21.01.83.05.16.88.312.918.01.01.82.95.06.78.112.617.61.22.23.66.08.19.815.221.3容量変化表 : M2形039

元のページ  ../index.html#41

このブックを見る